Noise-Compensated, Bias-Corrected Diffusion Weighted Endorectal Magnetic Resonance Imaging via a Stochastically Fully-Connected Joint Conditional Random Field Model

12/15/2015
by   Ameneh Boroomand, et al.
0

Diffusion weighted magnetic resonance imaging (DW-MR) is a powerful tool in imaging-based prostate cancer screening and detection. Endorectal coils are commonly used in DW-MR imaging to improve the signal-to-noise ratio (SNR) of the acquisition, at the expense of significant intensity inhomogeneities (bias field) that worsens as we move away from the endorectal coil. The presence of bias field can have a significant negative impact on the accuracy of different image analysis tasks, as well as prostate tumor localization, thus leading to increased inter- and intra-observer variability. Retrospective bias correction approaches are introduced as a more efficient way of bias correction compared to the prospective methods such that they correct for both of the scanner and anatomy-related bias fields in MR imaging. Previously proposed retrospective bias field correction methods suffer from undesired noise amplification that can reduce the quality of bias-corrected DW-MR image. Here, we propose a unified data reconstruction approach that enables joint compensation of bias field as well as data noise in DW-MR imaging. The proposed noise-compensated, bias-corrected (NCBC) data reconstruction method takes advantage of a novel stochastically fully connected joint conditional random field (SFC-JCRF) model to mitigate the effects of data noise and bias field in the reconstructed MR data. The proposed NCBC reconstruction method was tested on synthetic DW-MR data, physical DW-phantom as well as real DW-MR data all acquired using endorectal MR coil. Both qualitative and quantitative analysis illustrated that the proposed NCBC method can achieve improved image quality when compared to other tested bias correction methods. As such, the proposed NCBC method may have potential as a useful retrospective approach for improving the consistency of image interpretations.

READ FULL TEXT

page 1

page 4

page 6

page 7

page 8

research
07/26/2020

Joint reconstruction and bias field correction for undersampled MR imaging

Undersampling the k-space in MRI allows saving precious acquisition time...
research
12/25/2015

Sparse Reconstruction of Compressive Sensing MRI using Cross-Domain Stochastically Fully Connected Conditional Random Fields

Magnetic Resonance Imaging (MRI) is a crucial medical imaging technology...
research
07/30/2023

Unsupervised Decomposition Networks for Bias Field Correction in MR Image

Bias field, which is caused by imperfect MR devices or imaged objects, i...
research
01/10/2013

3T MR-Guided Brachytherapy for Gynecologic Malignancies

Gynecologic malignancies are a leading cause of death in women worldwide...
research
09/27/2022

LapGM: A Multisequence MR Bias Correction and Normalization Model

A spatially regularized Gaussian mixture model, LapGM, is proposed for t...
research
12/17/2017

Attenuation Correction for Brain PET imaging using Deep Neural Network based on Dixon and ZTE MR images

Positron Emission Tomography (PET) is a functional imaging modality wide...
research
01/11/2022

An analysis of reconstruction noise from undersampled 4D flow MRI

Novel Magnetic Resonance (MR) imaging modalities can quantify hemodynami...

Please sign up or login with your details

Forgot password? Click here to reset