Non-quadratic convex regularized reconstruction of MR images from spiral acquisitions

08/22/2009
by   R. Boubertakh, et al.
0

Combining fast MR acquisition sequences and high resolution imaging is a major issue in dynamic imaging. Reducing the acquisition time can be achieved by using non-Cartesian and sparse acquisitions. The reconstruction of MR images from these measurements is generally carried out using gridding that interpolates the missing data to obtain a dense Cartesian k-space filling. The MR image is then reconstructed using a conventional Fast Fourier Transform. The estimation of the missing data unavoidably introduces artifacts in the image that remain difficult to quantify. A general reconstruction method is proposed to take into account these limitations. It can be applied to any sampling trajectory in k-space, Cartesian or not, and specifically takes into account the exact location of the measured data, without making any interpolation of the missing data in k-space. Information about the expected characteristics of the imaged object is introduced to preserve the spatial resolution and improve the signal to noise ratio in a regularization framework. The reconstructed image is obtained by minimizing a non-quadratic convex objective function. An original rewriting of this criterion is shown to strongly improve the reconstruction efficiency. Results on simulated data and on a real spiral acquisition are presented and discussed.

READ FULL TEXT

page 7

page 8

page 9

research
07/21/2021

High-Resolution Pelvic MRI Reconstruction Using a Generative Adversarial Network with Attention and Cyclic Loss

Magnetic resonance imaging (MRI) is an important medical imaging modalit...
research
07/24/2023

Global k-Space Interpolation for Dynamic MRI Reconstruction using Masked Image Modeling

In dynamic Magnetic Resonance Imaging (MRI), k-space is typically unders...
research
01/11/2022

An analysis of reconstruction noise from undersampled 4D flow MRI

Novel Magnetic Resonance (MR) imaging modalities can quantify hemodynami...
research
08/04/2020

Fast Nonconvex T_2^* Mapping Using ADMM

Magnetic resonance (MR)-T_2^* mapping is widely used to study hemorrhage...
research
07/26/2020

Joint reconstruction and bias field correction for undersampled MR imaging

Undersampling the k-space in MRI allows saving precious acquisition time...
research
08/26/2019

Accelerated Motion-Aware MR Imaging via Motion Prediction from K-Space Center

Motion has been a challenge for magnetic resonance (MR) imaging ever sin...
research
11/13/2022

FIRES: Fast Imaging and 3D Reconstruction of Archaeological Sherds

Sherds, as the most common artifacts uncovered during archaeological exc...

Please sign up or login with your details

Forgot password? Click here to reset